The call button is used to activate the alarm
in applications where a pull cord is unsuitable
(Building Control should be consulted first as
only pull cords are recommended in Building
Regulations).
Installation
The call button should be mounted at between 800mm to
1000mm with a lower call button mounted at 100mm from
the floor. The call button is finished in brushed stainless steel
with a blue indicator for the visual alarm.
For simplicity, all wiring is a standard two core cable, the
wiring order of the plates is not fixed and therefore can be
wired in any order to give flexibility in the installation routes.
Each plate has two sets of two part terminals allowing simple
cable connections. There is a maximum number of 6 call
plates on a single line, with the last one operated registering.
Operation - Pressing the button once will activate the alarm, it will then
illuminate and sound to confirm the alarm state.
The ViAC-CLP-SS Assist Call, call plate is fully
compatible with the Lexicomm EVC range of
equipment and the standalone Assist Call range.
• Compact design
• BS 8300-2:2018 “Acknowledge” feature
• Blue indication
• Flush or surface mounting
• Braille enhanced call button
• Stainless steel finish